FastDigest HindIII (Thermo Scientific) For additional convenience FastDigest Green Buffer includes a density reagent and two tracking dyes for direct loading of digestion reaction products on gels. Short incubation times and optimal composition of the universal FastDigest Buffer eliminate star activity effects.The FastDigest HindIII restriction enzyme recognizes AAGCTT sites and cuts best at 37C in 515 minutes using universal FastDigest Buffer. Brand: Thermo Scientific FD0505 thermo fastdigest hindiii

5 Thermo Scientific FastDigest HindIII restriction enzyme recognizes AAGCTT site and cuts best at 37C in 515 minutes using universal FastDigest Buffer. Thermo Scientific FastDigest HindIII is one of an advanced line of fast restriction enzymes that are all 100 active in the universal FastDigest and FastDigest Green reaction buffers.

Thermo Scientific FastDigest HindIII The FastDigest HindIII restriction enzyme recognizes AAGCTT sites and cuts best at 37C in 515 minutes using universal FastDigest Buffer. Brand: Thermo Scientific FD0504 Thermo Scientific FastDigest HindIII. The FastDigest HindIII restriction enzyme recognizes AAGCTT sites and cuts best at 37C in 515 minutes using universal FastDigest Buffer.thermo fastdigest hindiii Thermo Scientific HindIII restriction enzyme recognizes AAGCTT sites and cuts best at 37C in R buffer. See Reaction Conditions for Restriction Enzymes for a table of enzyme activity, conditions for double digestion, and heat inactivation for this and other restriction enzymes. Note: Also available as a FastDigest enzyme for rapid DNA digestion.

Rating: 4.58 / Views: 505

Thermo fastdigest hindiii free

Incubation at 37C. 1 L of FastDigest HindIII is formulated to digest up to: 1 g of lambda DNA in 5 min. 1 g of plasmid DNA in 15 min. 0. 2 g of PCR product in 20 min. 1 g of genomic DNA in 10 min, or 5 g of genomic DNA in 30 min. Thermal Inactivation: Incubation at 80C for 10 min. thermo fastdigest hindiii FastDigest enzymes can be used to digest plasmid, genomic and viral DNA as well as PCR products and do not show star activity even in prolonged incubations. Enzymes used in common downstream applications such as ligation, blunting and dephosphorylation reactions also have 100 activity in FastDigest and FastDigest Green Buffer. How can the answer be improved? Thermo Scientific FastDigest HindIII The FastDigest HindIII restriction enzyme recognizes AAGCTT sites and cuts best at 37C in 515 minutes using universal FastDigest Buffer.